Western blotting is a robust technique employing antibodies to detect proteins immobilized on a blotting membrane after separation by electrophoresis. The technique can be performed either directly or indirectly. Each method can offer advantages depending on the experimental requirements.

Once proteins have been separated by gel electrophoresis and transferred onto a blotting membrane, Western blotting can be performed in either one or two steps.

Direct – One step method

In the direct detection method (Figure 1 (A)), a primary antibody directly conjugated to a reporter enzyme or fluorescent dye is used to detect the protein antigen on the blotting membrane after a single incubation step. Although this one step method is quicker, it is not widely used. Figure 1(B) illustrates one of the problems of directly conjugating the primary antibody, whereby the reporter molecule can occlude the antigen binding region of the primary antibody, preventing good recognition of the antigen and leading to reduced sensitivity. Excess primary may compensate for this effect but may lead to poor reproducibility and increased background.

Indirect – Two step method

The two step, indirect detection method of Western blotting avoids such interference with antigen detection. An unlabeled primary antibody forms a complex with the antigen bound to the blot membrane. After washing, the blot is incubated with a secondary antibody conjugated with the reporter enzyme or fluorophore. Multiple secondary antibodies bind to epitopes on the primary antibody, creating a labeled antigen-antibody complex (Figure 1(C)). Although the indirect method requires one more wash and incubation step, it presents numerous advantages over the direct method, including amplification of signal and flexibility.

 

3 types of indirect

Figure 1: (A) Directly conjugated primary antibody binds antigen bound to membrane. (B) Directly conjugated primary antibody binds poorly to antigen bound to membrane, since reporter enzyme or fluorophore can conjugate into antigen-binding region and reduce affinity of the antibody for its target. Using a secondary eliminates this. (C) Indirect method – multiple conjugated secondary antibodies bind to an unconjugated primary antibody.

 

The advantages and disadvantages of the direct and indirect detection methods are detailed in the table below. They apply to Western blotting but may also be relevant to other techniques, such as IHC/ICC, ELISA and Flow Cytometry.

 

Table 1: Advantages and disadvantages of direct and indirect Western blotting methods.

Direct Detection Method Indirect detection method
Disadvantages Advantages Disadvantages Advantages
Time Labeling individual primary antibodies is time-consuming. One incubation step means that direct detection methods can be rapid. The addition of the secondary antibody incurs extra steps. Many reliable commercially available labeled secondaries reduce time consuming optimization steps.
Flexibility and availability The number of conjugated primary antibodies is limited. Secondary antibodies offer a wide range of conjugate options and antibody specificities.
Sensitivity The signal from direct method may appear weaker than indirect method. Signal amplification – each primary antibody can accommodate multiple secondary antibodies, increasing the number of molecules available to produce signal.
Immunoreactivity Primary antibodies may have reduced immunoreactivity due to conjugate interference with antigen binding. Immunoreactivity of the primary antibody is preserved, and signal is provided by the conjugated secondary.
Cost Conjugated  primary antibodies may be expensive, and more antibody may be required to counteract loss of sensitivity. One secondary antibody can be used to detect any primary antibody raised in the same host  species, reducing cost.
Signal enhancement options Sample concentration may be required for low abundance proteins prior to loading. Secondary antibodies can be used to enhance signal in numerous ways. 

 

 


References:

Alberts B et al (1994) Molecular biology of the Cell. 3rd Ed. Garland press. London

Roitt et al (2005) Immunology. 6th Ed. Mosby. Spain

Comments are closed.

  • Recent Posts

    • What is an Antibody?

      Download PDF Antibodies are complex proteins produced by mammalian B cells during the adaptive immune response. Their unique ability to bind a broad array of targets with high specificity and …Read More »
    • Secondary detection: Indirect detection set-up

      Download PDF Secondary detection, also known as indirect detection, has two important advantages over direct detection. These are its capacity for signal amplification, which can increase researchers’ chances of identifying …Read More »
    • Top 10 Tips for ELISA

      Download PDF Enzyme-linked immunosorbent assay (ELISA) remains one of the most popular immunoassay techniques due to its ease of use, high sensitivity, and ability to provide quantitative results. It can …Read More »
    • We’d like to hear from you!

      Download PDF As we reflect on 2023, we want to hear from our loyal Jackson ImmunoResearch customers. Complete our customer satisfaction survey and we’ll send you an exclusive JIR T-shirt! …Read More »
    • Considerations for Multiplex Immunofluorescence

      Download PDF A major advantage of fluorescent detection is that it allows for multiplexing. Depending on the immunoassay technique being performed, as many as 20 or more different analytes can …Read More »